Contact 800-252-8714

  1. pin-int

Rinnai® Luxury Series REU-VC2837FFUD-US RL94IP Non-Condensing Tankless Water Heater, 10300 to 199000 Btu/hr, 120 W

  • Manufacturer: Rinnai Corporation
  • Brand Name: Rinnai®
  • Part#: RINRL94IP
  • MPN: RL94IP
  • Min. Order Qty: 1
  • Qty. Interval: 1
  • loading Available at All Branches

Rinnai® Non-Condensing Tankless Water Heater, Luxury Series, Model: REU-VC2837FFUD-US, 10300 to 199000 Btu/hr, 120 W, 0.26 to 9.8 gpm Flow Rate, 0.82 Energy Factor, 4.7 gph, 6.6 gph Recovery Rate, Direct Vent, 4/8/10 A, 120 V, 60 Hz, MNPT Connection, 20 to 150 psi, LP Gas Fuel, Direct Electronic Ignition System, 98 to 140 deg F, 23 in H x 14 in W x 9 in D

Amperage Rating      :      4/8/10 A
BTU Rating      :      10300 to 199000 Btu/hr
Connection Type      :      MNPT
Dimensions      :      23 in H x 14 in W x 9 in D
Energy Factor      :      0.82
Flow Rate      :      0.26 to 9.8 gpm
Frequency Rating      :      60 Hz
Fuel Type      :      LP Gas
Ignition System      :      Direct Electronic
Model      :      REU-VC2837FFUD-US
Power Rating      :      120 W
Pressure Rating      :      20 to 150 psi
Recovery Rate      :      4.7 gph, 6.6 gph
Series      :      Luxury Series
Temperature Rating      :      98 to 140 deg F
Vent Type      :      Direct
Voltage Rating      :      120 V
  • Temperature controlled, continuous flow, gas hot water system
  • Isolation and pressure relief valves included - isolation valves are certified to NSF/ANSI 61 for potable water
  • Water flow control, water flow sensor, electronic water control device and by-pass
  • Built-in Rinnai® Circ-Logic recirculation program cycles external pump control
  • Water temperature control, simulation feed forward and feedback
  • Controller cables non-polarized 2-core cable, minimum 22 AWG wire
  • Complies with south coast air quality management district 40 ng/J or 55 mg/L NOx emission levels
  • Minimum 8 in WC, maximum 13-1/2 in-WC gas supply pressure
  • High-fire 4.7 in WC, low fire 0.87 in-WC manifold gas pressure
  • Safety devices - flame failure - flame rod, boiling protection, combustion fan rpm check, over current - glass fuse, remaining flame (OHS), thermal fuse, automatic frost protection
  • Forced combustion