Lochinvar® Knight™ Fire Tube Boiler, 120 V, 95 % AFUE, 8.5 to 85 MBtu/hr BTU, 2.2 gal Capacity, Automatic Vent, Chimney/Breeching/Vent Size: 2 in, 15 A Fuse, Direct Spark Ignition, Net Rating: 69 MBtu/hr, Wall Mounting, Additional Information: 79 MBtu/hr Heating Capacity
| AFUE Rating |
: |
95 % |
| Additional Information |
: |
79 MBtu/hr Heating Capacity |
| BTU Rating |
: |
8.5 to 85 MBtu/hr |
| Capacity |
: |
2.2 gal |
| Chimney/Breeching/Vent Size |
: |
2 in |
| Fuse Rating |
: |
15 A |
| Ignition Type |
: |
Direct Spark |
| Mounting Type |
: |
Wall |
| Net Rating |
: |
69 MBtu/hr |
| Vent Type |
: |
Automatic |
| Voltage Rating |
: |
120 V |
- Stainless steel heat exchanger allows system water to flow around specially designed tubes for maximum heat transfer, while providing protection against flue gas corrosion
- Combustion chamber access cover allows access to the combustion side of the heat exchanger
- The blower pulls in air and gas through the venture
- Air and gas mix inside the blower and are pushed into the burner, where they burn inside the combustion chamber
- The gas valve senses the negative pressure created by the blower, allowing gas to flow only if the gas valve is powered and combustion air is flowing
- The venture controls air and gas flow into the burner
- This sensor monitors the flue gas exit temperature
- The control module will modulate and shut down the boiler if flue gas temperature gets too hot
- This protects the flue pipe from overheating
- Boiler outlet temperature sensor (housed with the high limit sensor) monitors boiler outlet water temperature (system supply)
- If selected as the controlling sensor, the control module adjusts the boiler firing rate so the outlet temperature is correct
- Boiler inlet temperature sensor monitors return water temperature (system return)
- If selected as the controlling sensor, the control module adjusts the boiler firing rate so the inlet temperature is correct
- Temperature and pressure gauge (field installed, not shown) monitors the outlet temperature of the boiler as well as the system water pressure
- Electronic LCD display features a high resolution liquid crystal screen, three buttons and a navigation dial
- A serial and USB port support additional communication with the control
- Flue pipe adapter llows for the connection of the vent system to the boiler
- Burner made with metal fiber and stainless steel construction, the burner uses pre-mixed air and gas and provides a wide range of firing rates
- Gas threaded pipe connection
- This pipe should be connected to the incoming gas supply for the purpose of delivering gas to the boiler