NOBLE® is easy to install, setup and service and promises to deliver the lasting reliability and serviceability the industry has come to expect from a Lochinvar® boiler.
Lochinvar® NOBLE® Fire Tube Boiler, 120 V, 0.70 A, 60 Hz Frequency, 1 ph, 95 % AFUE, 110000 Btu/hr BTU, 1.4 gal Capacity, 30 psi Pressure, Universal Vent Connection, Gas, Water Fuel, Direct Vent, Chimney/Breeching/Vent Size: 3 in, Direct Spark Ignition, Net Rating: 89 mbh, 7.33 sq-ft Area, Wall Mounting, Stainless Steel, Dimensions: 24 in H x 17-1/4 in W x 18 in D
| AFUE Rating |
: |
95 % |
| Amperage Rating |
: |
0.70 A |
| Area |
: |
7.33 sq-ft |
| BTU Rating |
: |
110000 Btu/hr |
| Capacity |
: |
1.4 gal |
| Chimney/Breeching/Vent Size |
: |
3 in |
| Connection Type |
: |
Universal Vent |
| Dimensions |
: |
24 in H x 17-1/4 in W x 18 in D |
| Frequency Rating |
: |
60 Hz |
| Fuel Type |
: |
Gas, Water |
| Ignition Type |
: |
Direct Spark |
| Material |
: |
Stainless Steel |
| Mounting Type |
: |
Wall |
| Net Rating |
: |
89 mbh |
| Phase |
: |
1 ph |
| Pressure Rating |
: |
30 psi |
| Vent Type |
: |
Direct |
| Voltage Rating |
: |
120 V |
- 10:1 turndown ratio
- Features SMART CONTROL™ operating control
- Outdoor reset control with outdoor air sensor
- Programmable system efficiency optimizers
- Three-pump control system pump, boiler pump, DHW pump
- Low voltage terminal strip - flow switch contacts, low water cut-off connection, system sensor contacts, outdoor air sensor contacts, cascade contacts
- Time clock for data logging - last 10 lockouts
- Low water flow safety control and indication
- Password security
- Built-in cascading sequencer for up to 8 units
- Modulating burner with 10:1 turndown - direct spark ignition, low NOx operation
- Condensate trap
- Automatic reset high limit
- Adjustable high limit with manual reset
- Zero clearances to combustible materials
-
Instruction/Installation Manual
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_NKB080N_Instruction_Installation_Manual.pdf
-
Specification Sheet
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_NKB080N_Specification_Sheet.pdf
-
Submittal
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_NKB080N_Submittal.pdf
-
Warranty Information
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_NKB080N_Warranty.pdf
-
Instruction/Installation Manual
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_NKB080N_Instruction_Installation_Manual.pdf
-
Specification Sheet
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_NKB080N_Specification_Sheet.pdf
-
Submittal
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_NKB080N_Submittal.pdf
-
Warranty Information