Lochinvar® Fire Tube Boiler, 120 VAC, 60 Hz, 1 ph Phase, 95 % AFUE Rating, 15.5 to 155 MBtu/hr, 144 mbh Capacity, 10 gpm Flow Rate, 30 psi, Natural Gas Fuel, Horizontal, Vertical Direct Vent, Modulating Burner, Chimney/Breeching/Vent Size: 3 in Vent, Direct Spark Ignition, 125 MBtu/hr Net BTU Rating, Floor Mounting, Stainless Steel, 43-3/8 in H x 16 in W x 19 in D, Domestic/Import: Domestic, Additional Information: 1/2 in Connection Size, 10 gpm Flow Rate, 30 psi Pressure
| AFUE Rating |
: |
95 % |
| Additional Information |
: |
1/2 in Connection Size, 10 gpm Flow Rate, 30 psi Pressure |
| BTU Rating |
: |
15.5 to 155 MBtu/hr |
| Burner Type |
: |
Modulating |
| Capacity |
: |
144 mbh |
| Chimney/Breeching/Vent Size |
: |
3 in Vent |
| Dimensions |
: |
43-3/8 in H x 16 in W x 19 in D |
| Domestic/Import |
: |
Domestic |
| Flow Rate |
: |
10 gpm |
| Frequency Rating |
: |
60 Hz |
| Fuel Type |
: |
Natural Gas |
| Ignition Type |
: |
Direct Spark |
| Material |
: |
Stainless Steel |
| Mounting Type |
: |
Floor |
| Net BTU Rating |
: |
125 MBtu/hr |
| Phase |
: |
1 ph |
| Pressure Rating |
: |
30 psi |
| Vent Type |
: |
Horizontal, Vertical Direct |
| Voltage Rating |
: |
120 VAC |
- Multi-color graphic LCD display with navigation dial, soft keys and Loch-N-Link® USB programming
- Three-boiler set point temperature inputs, plus domestic hot water prioritization
- Multiple size boiler cascade
- Lead lag
- Efficiency optimization
- Front end loading capability
- Programmable for three-reset temperature input
- SH night setback
- DHW night setback
- Anti-cycling
- Outdoor air reset curve
- Ramp delay
- Modulation factor control
- Boost temperature and time
- System pump with parameter for continuous operation
- Boiler pump with variable speed control
- Domestic hot water pump
- Domestic hot water recirculation
- DHW tank piped with priority in the boiler loop
- DHW tank piped as a zone in the system with the pumps controlled by the smart system DHW modulation limiting
-
Catalog
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_100301987_Catalog.pdf
-
Owners/User Manual
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_100301987_Owners_User_Manual.pdf
-
Service Manual
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_100301987_Service_Manual.pdf
-
Specification Sheet
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_100301987_Specification_Sheet.pdf
-
Submittal
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_100301987_Submittal.pdf
-
Warranty Information
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_100301987_Warranty.pdf
-
Warranty Information
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_100301987_Warranty_Information.pdf
-
Catalog
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_KHB110N_Catalog.pdf
-
Owners/User Manual
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_KHB110N_Owners_User_Manual.pdf
-
Service Manual
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_KHB110N_Service_ Manual.pdf
-
Specification Sheet
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_KHB110N_Specification_Sheet.pdf
-
Warranty Information
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_KHB110N_Warranty.pdf
-
Catalog
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_KHB110N_Catalog.pdf
-
Owners/User Manual
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_KHB110N_Owners_User_Manual.pdf
-
Service Manual
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_KHB110N_Service Manual.pdf
-
Service Manual
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_KHB110N_Service_ Manual.pdf
-
Specification Sheet
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_KHB110N_Specification_Sheet.pdf
-
Warranty Information
https://assets.unilogcorp.com/267/ITEM/DOC/Lochinvar_KHB110N_Warranty.pdf